DSC
Fire System Sensor 2WTA-B by Smoke,Thermal, Sounder & Relay
Fire System Sensor 2WTA-B by Smoke,Thermal, Sounder & Relay
Fire System Sensor 2WTA-B by Smoke,Thermal, Sounder & Relay
2WTA-B Series smoke detectors with isolated thermal sensors, sounders, and relays apply the guiding principles of installation ease, intelligence, and instant inspection.
Throughout the i³ Series, installation is simple with its installer-friendly base and plug-in design. The base accommodates a broad range of back box and direct mounting options and provides ample space for pre-wiring the device. To complete the installation, the i³ detectors plug into its base with a simple Stop-Drop ’N Lock action.
To reduce the likelihood of nuisance alarms, all i³ detectors are equipped with both drift compensation and smoothing algorithms. These capabilities minimize both short- and long-term causes of nuisance alarms, such as RF interference and dust accumulation.
When connected to the 2W-MOD2 loop test/maintenance module or an i3 Ready™ panel, 2‑wire i3 detectors can generate a remote maintenance signal when in a maintenance or freeze trouble condition. To measure the sensitivity of any i³ detector, the SENS-RDR displays the reading, in terms of percent-per-foot obscuration, within seconds.
i³ detectors have red and green LEDs to simplify local status indication during power-up, standby, alarm, maintenance, and freeze trouble conditions. If connected to the RRS-MOD reversing relay/synchronization module, all i³ sounders on the loop will activate when one detector is in alarm. The RRS-MOD also synchronizes i³ sounder output to ensure a clear audible signal.
Should the application call for differentiating between a local and a general alarm, the isolated thermal model initiates a local alarm when smoke is detected and a general alarm when the thermal sensor is activated.Features & Benefits:
- 85 dB sounder
- Form C relay
- Isolated thermal sensor
- Plug-in design (base included)
- In-line terminals
- Flexible mounting options
- Stop-Drop ’N Lock™ attachment to the base
- Removable cover and chamber
- Remote maintenance signaling
- Drift compensation and smoothing algorithms
- Simplified sensitivity measurement
- Dual-color LEDs
Certifications:
- UL Listed S911
- FM Approved 3015195
- CSFM Listing 7272-1653:164
- MEA Approved 372-02-E
- MSFM Approved 2133
- ETL Listed 3180932
- C2WTA-BA: ULC Listed
- C2WTR-BA: ULC Listed
- C4WT-BA: ULC Listed
- C4WTA-BA: ULC Listed
- C4WTR-BA: ULC Listed
- C4WTAR-BA: ULC Listed
- C4WITAR-BA: ULC Listed